Customization: | Available |
---|---|
Usage: | Laptop, Game Player, Digital Camera, Display, Device Charging, Replacement PSU, Universal PSU |
Output Type: | DC |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
* Consume electronics
* Instrumentation
* Technology
* Home appliances
* Gadgets
We would like to ask you:
Has your company encountered or is being troubled by any of the following issues caused by external power adapters directly or indirectly?
1. Insufficient power output, leading to device malfunctions.
2. Overheating adapters, posing fire hazards.
3. Inadequate protection mechanisms, risking explosions or electric shock accidents.
4. Short product lifespan, requiring frequent replacements.
5. High cost of OEM (original) power supply, necessitating cost efficient alternatives.
6. Non-compliance with safety regulations, hindering market entry for your devices.
7. Excessive ripple noise, degrading audio equipment sound quality unplesantly.
8. Electromagnetic interference, reducing touchscreen responsiveness.
9. Overwhelming options, struggling to identify reliable suppliers.
If any of these resonate with your situation, we're here to help. A single telephone-communication or email or message can resolve your issues with our tailored solutions.
Rated input voltage | 100-240Vac |
Operating range | 90-264Vac |
Rated input frequency | 50/60Hz |
Variation Frequency | 50/60Hz +/- 3Hz |
Rated input current | 0.7 A Max. |
Primary current protection | An adequate internal fuse on the AC input line is installed |
Power consumption (no loading) | 0.1W Max. (Input voltage 115V and 230V) |
Configuration | Class II Conductor |
Dc output voltage | 12.0V |
Minimum load current | 0A |
Rating load current | 2.5A |
Rating output power | 30.0W |
Line regulation | The line regulation is less than ±5% while measuring at rated load and ±10% of input voltage changing. |
Load regulation | The load regulation for +12V is less than ±5%, at measured output load from 0% to 100% rated load . |
Ripple and noise | 120mVp-p Max. |
At 115/230Vac input and output Min and Max.Load, the ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF, crossed connected at testing point. | |
Average Efficiency | 86.95% Min, At 115/230Vac input voltage,1/4,1/2,3/4 and full load calculation average efficiency. Adaptor meet efficiency level VI of DOE and Erp. |
10% Load Efficiency | 76.95%Min At 115/230Vac input voltage,10% load efficiency. |
Turn on delay time | 3Second Max.at 115Vac-230Vac input and output Max.load. |
Rise time | 20 mS Max.at 115Vac input and output Max load. |
Hold up time | 10 mS Min.at 115Vac input and output Max.Load. |
Over-shoot | 10% Max.When power supply at turn off/on. |
Over voltage protection | The power supply shall be hiccup mode, when the output is over voltage, and the power supply shall not be damaged and shall be self-recovery when the fault condition is removed. |
Over current protection | The power supply will be auto recovered when over current faults remove. |
Short circuit protection | The power supply will be auto recovered when short circuit faults remove. |
Temperature | Operating/: 0 oC +40 oC |
Non-Operating/: -20 oC +80 oC | |
Humidity | Operating: 10%~90% (Non Condensing) |
Non-Operating: 10%~90% (Non Condensing) |
For short | Country | Certified Status | Standard |
GS | Europe | MEET | EN 62368-1 |
CE | Europe | MEET | EN 62368-1 |
UL | USA | MEET | UL 62368-1 |
CUL | Canada | MEET | CAN/CSA C22 2 NO.62368-1-14 |
FCC | USA | MEET | FCC PART15 |
UKCA | Britain | MEET | BS EN62368-1 |
SAA | AU | MEET |
SAA:AS/NZS 62368.1
|
PSE | Japan | MEET | J62368-1 |
Radiated and Conducted Emission | EN55032, Class B for radiated and conducted emissions FCC part 15: Class B for radiated and conducted emissions GB9254, GB17625.1 |
Electrostatic Discharge Immunity |
EN 61000-4-2
energy storage capacitance of 150pF, and discharge resistance of 330Ω, 8KV air discharge, 4KV contact discharge. |
Radiated Field Immunity |
EN 61000-4-3 Frequency Range: 80-1000MHz Field Strength: 3 V/m with 80% amplitude modulation of 1 kHz Performance Criteria A Radio-frequency electromagnetic field susceptibility test, RS 80-1000MHz, 3V/m, 80%AM(1KHz) |
Fast Transient Immunity |
EN 61000-4-4
|
Surge Immunity |
EN 61000-4-5
lines and cross primary ac input and secondary GND |
Power adapter size information:
Size: 71.3x43.3x38.5mmDie-cut partition A size | 474x115x2mm (Length, height, thickness) |
Die-cut partiton B size | 387x115x2mm (Length, hight, thickness) |
Paper panel size | 470x390mm (Length, width) |
Carton size | 490x405x260mm (Length, width, height) |
CUSTOM OPTIONS
Custom output voltage and current please see the following sheet
Output voltage VDC | Output current Amp | Max ouput power Wattage |
5.0-5.9 | 0.01-4.0 | 20W |
6.0-7.9 | 0.01-4.0 | 24W |
8.0-15.9 | 0.01-3.0 | 30W |
16.0-25.0 | 0.01-1.87 | 30W |